Olympus (BX43)

Olympus BX43

Olympus

MODEL: BX43

Light Intensity Manager Controls Brightness

Low Magnification Condenser U-LC

Various Units to Accommodate Observation Style

BX43 specifications

Microscope frame
Optical system
UIS2 optical system
Focus
Vertical stage movement: 25 mm stage stroke with coarse adjustment limit stopper, Torque adjustment for coarse adjustment knobs, Stage mounting position variable, High sensitivity fine focusing knob (minimum adjustment gradations: 1 µm)
Illuminator
Built-in Koehler illumination for transmitted light, light intensity manager switch
High color reproductivity LED light source, 6 V 30 W halogen bulb (pre-centered)
Revolving nosepiece
Interchangeable reversed quintuple/coded quintuple/sextuple/septuple/coded septuple nosepiece
Observation tube
Widefield (F.N. 22)
• Widefield tilting, telescopic and lifting binocular
   • Widefield tilting trinocular    • Widefield trinocular    • Widefield erect image trinocular    • Widefield tilting binocular    • Widefield ergo binocular    • Widefield binocular
Super widefield (F.N. 26.5)
• Super widefield trinocular    • Super widefield erect image trinocular
Stage
Ceramic-coated coaxial stage with left or right hand low drive control: with rotating mechanism and torque adjustment mechanism, optional rubber grips available (Non stick grooved coaxial, plain, rotatable stages are also available)
Condenser
• Abbe (N.A. 1.1), for 4x–100x
• Swing out Achromatic (N.A. 0.9), for 1.25x–100x (swing-out: 1.25x–4x)
• Achromatic Aplanatic (N.A. 1.4), for 10x–100x
• Phase contrast, darkfield (N.A. 1.1), [phase contrast: for 10x–100x, darkfield: for 10x–100x (up to N.A. 0.80)]
• Universal (N.A. 0.9), for 1.25x–100x [swing-out: 1.25x–4x, with oil top lens:(N.A. 1.4)]
• Low (N.A. 0.75), for 2x–100x (Dry)
• Ultra low (N.A. 0.16), for 1.25x–4x
• Darkfield dry (N.A. 0.8–0.92), for 10x–100x
• Darkfield oil (N.A. 1.20–1.40), for 10x–100x
Operating environment
• Indoor use
• Ambient temperature : 5 º to 40 ºC (41 º to 104 ºF)
• Maximum relative humidity : 80 % for temperatures up to 31º C (88 ºF), decreasing linearly through 70 % at 34 ºC
(93 ºF), 60 % at 37 ºC (99 ºF), to 50 % relative humidity at 40 ºC (104 ºF)
• Supply voltage fluctuations : Not to exceed ±10 % of the normal voltage

Note: We are Manufacturers, Suppliers, Exporters and Dealers of Various Olympus Microscope in Mumbai, Hyderabad, Bangalore, Pune, Ahmedabad, Chennai, Visakhapatnam, Surat, Nashik, Warangal, Vijayawada, Coimbatore, Vadodara, Navi Mumbai, Thane, Maharashtra, Goa, Gujarat, etc.