Tablet Disintegration Test Apparatus
- Home
- Tablet Disintegration Test Apparatus
Tablet Disintegration Test Apparatus
MODEL: 40TDA01
- TABLET DISINTEGRATION TEST APPARATUS is a Microprocessor based instrument designed for accurate determination of disintegration time of tables, capsules, as per IP/BP/USP standard. These tests are carried out by quality control and R & D departments in pharmaceutical industry. Two hotplates are provided to maintain the temp. of the liquid media (1000ml beaker). Two batches of six tablets each can be tested simultaneously. Solid state Heat Regulator is provided to control the heat of the Hotplate. A constant speed 30 RPM motor drive single bar up & down smoothly to lift two baskets. The stroke is adjusted as per the specifications. A simple & unique arrangement of loading & unloading the basket makes it user friendly.
- The Tablet Disintegration Test Apparatus assesses the time it takes for tablets to break down in a controlled environment, simulating digestive conditions. It ensures compliance with pharmacopeial standards and is crucial for quality control in tablet manufacturing.
- Digital pre-set Timer 99.59hr. is provided to set the integration time & to switch off the motor. In power failure, the non-volatile memory of the microprocessor remember the last mode of operation, and complete the test after the power supply is resumed.
SPECIFICATIONS:
- No. of Basket : Double Basket (2 x 6 Test)
- Stroke : 50mm. approx. 30 strokes/min.
- Timer : Microprocessor based preset timer 00.01 to 99.59 Hr. with alarm
- Display : Digital 12 min. Red LED for time
- Heat Control : Continuously variable Electronic heat control
- Dimension : 350W x 270 Dx 400mm H
- Weight : 11 Kg. approx.
We are pros in manufacturing and supplying Lab Tablet Disintegration Test Apparatus since 1986 more than 39 years we have various customize options GMP and Non-GMP model. We have well trained Team to handle any maintenance works.
OUR COMPLETED PROJECTS
GOOGLE REVIEW
FAQ
Can you supply Laboratory Tablet Disintegration Test Apparatus In Ahmedabad?
Yes, we do supply in all parts in Ahmedabad.
What is the temperature limit for DT?
Devices is generally specified as ambient to 45.0°C or 25.0°C to 40.0°C, with a temperature range of 20.0°C to 39.9°C being common.
What is the purpose of disintegration test apparatus?
The disintegration test is used to show how quickly the tablet breaks down into smaller particles, allowing for a greater surface area and availability of the drug when taken by a patient.
Do You Provide Tablet Disintegration Test Apparatus after Sale Service?
Yes, We Have Inhouse Engineers We do Provide AMC for Our Lab Tablet Disintegration Test Apparatus.
Note: We are Manufacturers, Suppliers, Exporters and Dealers of Tablet Disintegration Test Apparatus in Mumbai Hyderabad Bangalore Pune Ahmedabad Chennai Visakhapatnam Surat Nashik Warangal Vijayawada Coimbatore Vadodara Navi Mumbai Thane Maharashtra Goa Gujarat etc.